Electricity supply requirements | eControl electric Aga range cookers

eControl powered Aga range cookers require the following power supplies.

  • 1 x 32amp (2 & 4 oven Aga range cookers)
  • 1 x 40amp (3 oven Aga range cookers)
  • 1 x 40amp (5 oven cookers and any model with Instaheat upgrade)

Cooker switch should be an accessible outlet box in adjacent cupboard, within 30cm of the Aga range cooker.

The isolator should not be positioned immediately above or behind the cooker, but must be fitted no more than 1ft / 30cm away from the appliance.

The isolator may be separate from the connection point.

Do you have a module/companion conventional cooker,  and are you considering the Classic system? In that case you will need an additional 32amp or 40amp supply for your 3 oven or 4 oven Aga range cooker. The main Aga range cooker is an entirely separate appliance to your module companion. They draw power separately. You cannot use the module supply for the Aga unless you want to remove the module, and only when the supply has been tested as sufficient. 

On some occasions electricians have helped our clients fit a 'switchover' that allows them to use either the module companion or the main Aga, never both at the same time. We defer to the expertise of your electrician in all cases.

 

Cooker Size Maximum potential draw Left Hob Right Hob Top Oven Bottom Oven Left Oven Warming Cupboard
2 oven 6.0 kwh 2000w 1500w

1000w - high

750w - low

750w / /
3 oven 7.5 kwh 2000w 1500w

1000w - high

750w - low

750w

750w - high

750w - low

/

4 oven

6.75 kwh 2000w 1500w

1000w - high

750w - low

750w / 750w
5 oven

8.25kW

 

2000w 1500w

1000w - high

750w - low

750w

750w - high

750w - low

750w


Instaheat ceramic instant hotplate upgrade (more info)
  • Does not require an additional supply but ANY model including the Instaheat upgrade requires a 40amp supply.

Before we attend

  • The electricity supply will need to be ready and certified by your electrician. We will bring a handy file in which to store your certificate with your Blake & Bull user information. We will need photos of your electrics once set up.

eControl Aga electrical requirements diagram 